{"id":465,"date":"2020-07-07T12:17:08","date_gmt":"2020-07-07T10:17:08","guid":{"rendered":"http:\/\/localhost\/geosys\/lubrikator\/"},"modified":"2021-11-15T15:10:07","modified_gmt":"2021-11-15T14:10:07","slug":"well-pressure-control-unit","status":"publish","type":"page","link":"https:\/\/geosys-swiss.com\/en\/well-pressure-control-unit\/","title":{"rendered":"Well-Pressure-Control-Unit"},"content":{"rendered":"<div class=\"grid-container\">\n\t<div class=\"grid-100\">\n                 <h1>Well-Pressure-Control-Unit<\/h1>\n\t<\/div>\n\t<div class=\"grid-50 tablet-100 mobile-100\">\n               <p>The GeoSys Well-Pressure-Control-Unit is employed in the oil and gas exploration industry in order to operate boreholes that are under high pressure. Through this control unit, the insertion of logging tools, without the leakage of harmful gases, is facilitated.<\/p>\n               <p>The Well-Pressure-Control-Unit is a large pipe construction which can be installed vertically onto the borehole, which is under high pressure. The upper part of the construction consists of the Cable Wiper and the Grease Head Injector. The logging tool is put into the Lightweight Lubricator, which is located below the Grease Head Injector. In order to lower the logging tool into the well, all valves between the Lubricator and the borehole are opened. Consequently, the pressure in the Lubricator equals the borehole pressure. Thus, the logging tool can be lowered into the borehole. During this whole operation the Cabel Wiper and the Grease Head Injector avoid a leakage of gas through the cable port.<\/p>\n               <p>In order to retrieve the logging tool from the borehole, the tool is being pulled up into the Lightweight Lubricator. Following, all valves below the Lubricator are being closed. The excess pressure in the Lubricator is being discharged, which is necessary to retrieve the logging tool from the Lubricator.<\/p>\n\t<\/div>\n\t<div class=\"grid-50 tablet-100 mobile-100\">\n               <img src=\"https:\/\/geosys-swiss.com\/wp-content\/uploads\/2020\/10\/lubrikator.jpg\" alt=\"Well-Pressure-Control-Unit\" \/>\n\t<\/div>\n<\/div>\n\n<div class=\"grid-container\">\n\t<div class=\"grid-100\">\n\t\t<h2 class=\"custom-h2 secondary-color\">Construction<\/h2>\n                <p>The lubricator is composed as follows from bottom to top:<\/p>\n                <p class=\"tm30\"><\/p>\n                <p><strong>BOP \u2013 Blow \u2013 Out Preventer<\/strong><br>This device ensures that no harmful gases are discharging into the environment.<\/p>\n                <p><strong>Tool Trap (\u201eSondenf\u00e4nger\u201c)<\/strong><br>The Tool Trap is a safety device which protects the logging tool from falling into the borehole.<\/p>\n                <p><strong>Quick Test Assembly<\/strong><br>This device enables a quick and easy validation of pressure seals.<\/p>\n                <p><strong>Lightweight Lubricator<\/strong><br>The Lubricator facilitates the collection of the logging tool and can be extended or shortened through the utilisation of pipes.<\/p>\n                <p><strong>Head Catcher<\/strong><br>The Head Catcher is another safety device in order to protect the logging tool from falling into the borehole.<\/p>\n                <p><strong>Grease Head Injector<\/strong><br>This device enables a complete sealing around the cable.<\/p>\n                <p><strong>Kabelwischer<\/strong><br>The Cable Wiper facilitates in conjunction with the Grease Head Injector the sealing around the cable.<\/p>\n\t<\/div>\n<\/div>\n\n<div class=\"grid-container\">\n\t<div class=\"grid-100\">\n\t\t<h2 class=\"custom-h2\">Technical Specification of the Well-Pressure-Control-Unit<\/h2>\n\t\t<table class=\"custom-table\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<th>Cable Wiper<\/th>\n\t\t\t<th><\/th>\n\t\t\t<th><\/th>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><\/td>\n\t\t\t<td>Connection<\/td>\n\t\t\t<td>Acme Quick Union Type B, O<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><\/td>\n\t\t\t<td><\/td>\n\t\t\t<td>Whitworth<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><\/td>\n\t\t\t<td>Cable Sizes<\/td>\n\t\t\t<td>Up to 15\/32\u2033 11,91mm<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><\/td>\n\t\t\t<td>Weight<\/td>\n\t\t\t<td>21,43 kg<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<th>Grease Head Injector<\/th>\n\t\t\t<th><\/th>\n\t\t\t<th><\/th>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><\/td>\n\t\t\t<td>Cable Sizes<\/td>\n\t\t\t<td>All common sizes are sup-ported up to 15\/ 32\u2033 11,91mm<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><\/td>\n\t\t\t<td>Working Pressure<\/td>\n\t\t\t<td>Up to 10.000 PSI\/ 700 bar<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><\/td>\n\t\t\t<td>Service Environment<\/td>\n\t\t\t<td>Standard and Sour<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><\/td>\n\t\t\t<td>Connection<\/td>\n\t\t\t<td>Acme Quick Union Type B, O<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><\/td>\n\t\t\t<td><\/td>\n\t\t\t<td>Whitworth<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<th>Release Head Catcher<\/th>\n\t\t\t<th><\/th>\n\t\t\t<th><\/th>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><\/td>\n\t\t\t<td>Collet Size<\/td>\n\t\t\t<td><\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><\/td>\n\t\t\t<td>Inch<\/td>\n\t\t\t<td>1,00\u2033, 1,187\u2033, 1,375\u2033, 1,750\u2033, 2,313\u2033<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><\/td>\n\t\t\t<td>Millimeter<\/td>\n\t\t\t<td>25,4; 30,15; 34,92; 44,45; 58,75<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><\/td>\n\t\t\t<td>Working Pressure<\/td>\n\t\t\t<td>Up to 10.000 PSI\/ 700bar<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><\/td>\n\t\t\t<td>Service Environment<\/td>\n\t\t\t<td>Standard and Sour<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><\/td>\n\t\t\t<td>Connection<\/td>\n\t\t\t<td>Acme Quick Union Type B, O<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><\/td>\n\t\t\t<td><\/td>\n\t\t\t<td>Whitworth<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><\/td>\n\t\t\t<td>Weight<\/td>\n\t\t\t<td>49,48kg<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<th>Lightweight Lubricator<\/th>\n\t\t\t<th><\/th>\n\t\t\t<th><\/th>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><\/td>\n\t\t\t<td>Connection<\/td>\n\t\t\t<td>Acme Quick Union Type B, O<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><\/td>\n\t\t\t<td><\/td>\n\t\t\t<td>Whitworth<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><\/td>\n\t\t\t<td>Service Environment<\/td>\n\t\t\t<td>Standard and Sour<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><\/td>\n\t\t\t<td>Incorporate design<\/td>\n\t\t\t<td>Dual seal<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><\/td>\n\t\t\t<td>Weight<\/td>\n\t\t\t<td>42 kg<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<th>Quick Test Assembly<\/th>\n\t\t\t<th><\/th>\n\t\t\t<th><\/th>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><\/td>\n\t\t\t<td>Connection<\/td>\n\t\t\t<td>Acme Quick Union Type B, O<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><\/td>\n\t\t\t<td><\/td>\n\t\t\t<td>Whitworth<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><\/td>\n\t\t\t<td>Service Environment<\/td>\n\t\t\t<td>Standard and Sour<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><\/td>\n\t\t\t<td>Working Pressure<\/td>\n\t\t\t<td>Up to 10.000 PSI\/ 700bar<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><\/td>\n\t\t\t<td>Size<\/td>\n\t\t\t<td>Available from 2,5\u2033\/ 63,5mm to 7\u2033\/ 177,8mm<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><\/td>\n\t\t\t<td>Side Port Connection<\/td>\n\t\t\t<td>Customer specified<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<th>Tool Trap<\/th>\n\t\t\t<th><\/th>\n\t\t\t<th><\/th>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><\/td>\n\t\t\t<td>Connection<\/td>\n\t\t\t<td>Acme Quick Union Type B, O<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><\/td>\n\t\t\t<td><\/td>\n\t\t\t<td>Whitworth<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><\/td>\n\t\t\t<td>Control<\/td>\n\t\t\t<td>Manual or Hydraulic<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><\/td>\n\t\t\t<td>Inner Dimensions<\/td>\n\t\t\t<td>Produced compatible to Lubri-cator<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><\/td>\n\t\t\t<td>Working Pressure<\/td>\n\t\t\t<td>Up to 10.000 PSI\/ 700bar<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><\/td>\n\t\t\t<td>Service Environment<\/td>\n\t\t\t<td>Standard and Sour<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<th>Blowout Preventer<\/th>\n\t\t\t<th><\/th>\n\t\t\t<th><\/th>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><\/td>\n\t\t\t<td>Connection<\/td>\n\t\t\t<td>Acme Quick Union Type B, O<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><\/td>\n\t\t\t<td><\/td>\n\t\t\t<td>Whitworth<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><\/td>\n\t\t\t<td>Size<\/td>\n\t\t\t<td>From 3,0625\u2033\/ 77,79mm to 7,0625\u2033\/ 179,39mm<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><\/td>\n\t\t\t<td>Hydraulic Operation Pressure<\/td>\n\t\t\t<td>3000 PSI\/ 306,8 bar<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><\/td>\n\t\t\t<td>Safety<\/td>\n\t\t\t<td>Manual Override<\/td>\n\t\t<\/tr>\n\t\t<tr>\n\t\t\t<td><\/td>\n\t\t\t<td>Service Environment<\/td>\n\t\t\t<td>Standard and Sour<\/td>\n\t\t<\/tr>\n\t<\/tbody>\n<\/table>\n\t<\/div>\n<\/div>\n\n","protected":false},"excerpt":{"rendered":"Well-Pressure-Control-Unit The GeoSys Well-Pressure-Control-Unit is employed in the oil and gas exploration industry in order to operate boreholes that are &#8230; <a title=\"Well-Pressure-Control-Unit\" class=\"read-more\" href=\"https:\/\/geosys-swiss.com\/en\/well-pressure-control-unit\/\" aria-label=\"More on Well-Pressure-Control-Unit\">Weiterlesen<\/a>","protected":false},"author":1,"featured_media":434,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v17.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Well-Pressure-Control-Unit | Geo Sys Geoger\u00e4te Swiss GmbH<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/geosys-swiss.com\/en\/well-pressure-control-unit\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Well-Pressure-Control-Unit | Geo Sys Geoger\u00e4te Swiss GmbH\" \/>\n<meta property=\"og:description\" content=\"Well-Pressure-Control-Unit The GeoSys Well-Pressure-Control-Unit is employed in the oil and gas exploration industry in order to operate boreholes that are ... Weiterlesen\" \/>\n<meta property=\"og:url\" content=\"https:\/\/geosys-swiss.com\/en\/well-pressure-control-unit\/\" \/>\n<meta property=\"og:site_name\" content=\"Geo Sys Geoger\u00e4te Swiss GmbH\" \/>\n<meta property=\"article:modified_time\" content=\"2021-11-15T14:10:07+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/geosys-swiss.com\/wp-content\/uploads\/2020\/07\/banner-title-draf2t.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"400\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Organization\",\"@id\":\"https:\/\/geosys-swiss.com\/#organization\",\"name\":\"Geo Sys - Ge\\u00f6ger\\u00e4te Swiss GmbH\",\"url\":\"https:\/\/geosys-swiss.com\/\",\"sameAs\":[],\"logo\":{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/geosys-swiss.com\/#logo\",\"inLanguage\":\"en-US\",\"url\":\"https:\/\/geosys-swiss.com\/wp-content\/uploads\/2021\/11\/geo-sys-swiss.svg\",\"contentUrl\":\"https:\/\/geosys-swiss.com\/wp-content\/uploads\/2021\/11\/geo-sys-swiss.svg\",\"caption\":\"Geo Sys - Ge\\u00f6ger\\u00e4te Swiss GmbH\"},\"image\":{\"@id\":\"https:\/\/geosys-swiss.com\/#logo\"}},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/geosys-swiss.com\/#website\",\"url\":\"https:\/\/geosys-swiss.com\/\",\"name\":\"Geo Sys Geoger\\u00e4te Swiss GmbH\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/geosys-swiss.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/geosys-swiss.com\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/geosys-swiss.com\/en\/well-pressure-control-unit\/#primaryimage\",\"inLanguage\":\"en-US\",\"url\":\"https:\/\/geosys-swiss.com\/wp-content\/uploads\/2020\/07\/banner-title-draf2t.jpg\",\"contentUrl\":\"https:\/\/geosys-swiss.com\/wp-content\/uploads\/2020\/07\/banner-title-draf2t.jpg\",\"width\":1920,\"height\":400},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/geosys-swiss.com\/en\/well-pressure-control-unit\/#webpage\",\"url\":\"https:\/\/geosys-swiss.com\/en\/well-pressure-control-unit\/\",\"name\":\"Well-Pressure-Control-Unit | Geo Sys Geoger\\u00e4te Swiss GmbH\",\"isPartOf\":{\"@id\":\"https:\/\/geosys-swiss.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/geosys-swiss.com\/en\/well-pressure-control-unit\/#primaryimage\"},\"datePublished\":\"2020-07-07T10:17:08+00:00\",\"dateModified\":\"2021-11-15T14:10:07+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/geosys-swiss.com\/en\/well-pressure-control-unit\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/geosys-swiss.com\/en\/well-pressure-control-unit\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/geosys-swiss.com\/en\/well-pressure-control-unit\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\/\/geosys-swiss.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Well-Pressure-Control-Unit\"}]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Well-Pressure-Control-Unit | Geo Sys Geoger\u00e4te Swiss GmbH","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/geosys-swiss.com\/en\/well-pressure-control-unit\/","og_locale":"en_US","og_type":"article","og_title":"Well-Pressure-Control-Unit | Geo Sys Geoger\u00e4te Swiss GmbH","og_description":"Well-Pressure-Control-Unit The GeoSys Well-Pressure-Control-Unit is employed in the oil and gas exploration industry in order to operate boreholes that are ... Weiterlesen","og_url":"https:\/\/geosys-swiss.com\/en\/well-pressure-control-unit\/","og_site_name":"Geo Sys Geoger\u00e4te Swiss GmbH","article_modified_time":"2021-11-15T14:10:07+00:00","og_image":[{"width":1920,"height":400,"url":"https:\/\/geosys-swiss.com\/wp-content\/uploads\/2020\/07\/banner-title-draf2t.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Organization","@id":"https:\/\/geosys-swiss.com\/#organization","name":"Geo Sys - Ge\u00f6ger\u00e4te Swiss GmbH","url":"https:\/\/geosys-swiss.com\/","sameAs":[],"logo":{"@type":"ImageObject","@id":"https:\/\/geosys-swiss.com\/#logo","inLanguage":"en-US","url":"https:\/\/geosys-swiss.com\/wp-content\/uploads\/2021\/11\/geo-sys-swiss.svg","contentUrl":"https:\/\/geosys-swiss.com\/wp-content\/uploads\/2021\/11\/geo-sys-swiss.svg","caption":"Geo Sys - Ge\u00f6ger\u00e4te Swiss GmbH"},"image":{"@id":"https:\/\/geosys-swiss.com\/#logo"}},{"@type":"WebSite","@id":"https:\/\/geosys-swiss.com\/#website","url":"https:\/\/geosys-swiss.com\/","name":"Geo Sys Geoger\u00e4te Swiss GmbH","description":"","publisher":{"@id":"https:\/\/geosys-swiss.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/geosys-swiss.com\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"ImageObject","@id":"https:\/\/geosys-swiss.com\/en\/well-pressure-control-unit\/#primaryimage","inLanguage":"en-US","url":"https:\/\/geosys-swiss.com\/wp-content\/uploads\/2020\/07\/banner-title-draf2t.jpg","contentUrl":"https:\/\/geosys-swiss.com\/wp-content\/uploads\/2020\/07\/banner-title-draf2t.jpg","width":1920,"height":400},{"@type":"WebPage","@id":"https:\/\/geosys-swiss.com\/en\/well-pressure-control-unit\/#webpage","url":"https:\/\/geosys-swiss.com\/en\/well-pressure-control-unit\/","name":"Well-Pressure-Control-Unit | Geo Sys Geoger\u00e4te Swiss GmbH","isPartOf":{"@id":"https:\/\/geosys-swiss.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/geosys-swiss.com\/en\/well-pressure-control-unit\/#primaryimage"},"datePublished":"2020-07-07T10:17:08+00:00","dateModified":"2021-11-15T14:10:07+00:00","breadcrumb":{"@id":"https:\/\/geosys-swiss.com\/en\/well-pressure-control-unit\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/geosys-swiss.com\/en\/well-pressure-control-unit\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/geosys-swiss.com\/en\/well-pressure-control-unit\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/geosys-swiss.com\/en\/"},{"@type":"ListItem","position":2,"name":"Well-Pressure-Control-Unit"}]}]}},"_links":{"self":[{"href":"https:\/\/geosys-swiss.com\/en\/wp-json\/wp\/v2\/pages\/465"}],"collection":[{"href":"https:\/\/geosys-swiss.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/geosys-swiss.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/geosys-swiss.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/geosys-swiss.com\/en\/wp-json\/wp\/v2\/comments?post=465"}],"version-history":[{"count":5,"href":"https:\/\/geosys-swiss.com\/en\/wp-json\/wp\/v2\/pages\/465\/revisions"}],"predecessor-version":[{"id":994,"href":"https:\/\/geosys-swiss.com\/en\/wp-json\/wp\/v2\/pages\/465\/revisions\/994"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/geosys-swiss.com\/en\/wp-json\/wp\/v2\/media\/434"}],"wp:attachment":[{"href":"https:\/\/geosys-swiss.com\/en\/wp-json\/wp\/v2\/media?parent=465"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}